According to the backstage kernel log, Antminer S17+ read the temp sensor failed, which means the temperature sensor chip is faulty. In this case, the hash board will not start, or the miner will stop running.
Troubleshooting:
So the first test is whether the voltage and resistance of No.51 and No.54 ASIC chips and their corresponding temperature sensor chips are abnormal. If they are abnormal, they need to re-solder or replace the faulty BM1397 chip. On the other hand, if the voltage and resistance values are normal, check whether the domain voltage and the 1.8V and 0.8V power supply of the same domain are normal.
Test method: Use the DC gear and diode gear of the fluke17B+ multimeter, connect the red test lead to the corresponding heat sink, and test with the black test lead.
Click the article below to learn more!
>>How to test the voltage and ground value of the Antminer S17+ hash board power supply unit?
Dear Customers,
Hello everyone, as China is about to usher in the Spring Festival, international logistics will be suspended. Zeus Mining is scheduled to stop shipping on January 18, 2025, and start the Spring Festival holiday from January 21 to February 4, 2025 (GMT+8). Pre-sales and after-sales service will reply to the information on February 5, 2025, and shipping will resume on February 8, 2025. Thank you for your support and trust in 2024. In 2025 and the future, we will bring better products and services to our friends.
Best wishes,
ZEUS MINING CO., LTD