ZEUS MINING
CRYPTO MINING PRO

Antminer S17+ read temp sensor failed - Antminer S17+ Kernel Log

According to the backstage kernel log, Antminer S17+ read the temp sensor failed, which means the temperature sensor chip is faulty. In this case, the hash board will not start, or the miner will stop running.

Antminer S17+ read temp sensor failed 

Troubleshooting:

So the first test is whether the voltage and resistance of No.51 and No.54 ASIC chips and their corresponding temperature sensor chips are abnormal. If they are abnormal, they need to re-solder or replace the faulty BM1397 chip. On the other hand, if the voltage and resistance values are normal, check whether the domain voltage and the 1.8V and 0.8V power supply of the same domain are normal.

BM1397 chip 

Test method: Use the DC gear and diode gear of the fluke17B+ multimeter, connect the red test lead to the corresponding heat sink, and test with the black test lead.

 

Click the article below to learn more!

>>Read Temp Sensor Failed

>>How to test the voltage and ground value of the Antminer S17+ hash board power supply unit?

0
About products purchase, please contact our sales manager:
[email protected]

About miner repair and after-sale issues, please contact the repair manager email:
[email protected]

For business cooperation, please contact:
[email protected]

COMPLAINTS & SUGGESTIONS
If you have any dissatisfaction during the transaction or have valuable suggestions for us, please contact us via this email address:
[email protected]
Attention!

Recently, many companies claiming to be mining companies imitate us and say that they are related to us, or that they are our branch companies, which has caused customers to be deceived. Please be careful not to believe any impostors, please check our correct contact information and beware of being deceived getting scammed, and losing money.
please check our right contact way: Here

CLOSE