When Antminer S17+ kernel log shows Chain 2 only find 0 asic, will cause miners to stop mining, you can troubleshoot by following steps.
Troubleshooting:
1. Swap the data cable of the Antminer S17+ hash board that displays "find 0 asic" with the data cables of the other two hash boards (only the hash board is replaced), thereby eliminating the problem of the data cable and Antminer S17+ control board.
2. Use the fluke17B+ multimeter to check whether the total voltage domain of the hash board is normal. If it is abnormal, you need to check whether the voltage of each PIC, MOS tube, and boost circuit is abnormal.
3. Check whether the voltage is normal by measuring the RI signal. First, in the middle domain, find the RI signal of a group of chips on the edge of the domain for detection. If it is normal, we will check it forward. If it is abnormal, check it backward. (the transmission direction of the RI signal is from the last chip to the first chip)
4. If the kernel log and test fixture detection show "ASIC=0 or NO hash board", check whether the chip's RI signal's voltage and the ground value are abnormal. If there is any abnormality, most of them are caused by chip pseudo soldering. Soldering twice first. If it cannot be solved, replace the faulty chip.
Click the article below to learn more!
>>Antminer Test Fixture for S17+, T17+, S17e, T17e, S19 series
Dear Customers,
Hello everyone, as China is about to usher in the Spring Festival, international logistics will be suspended. Zeus Mining is scheduled to stop shipping on January 18, 2025, and start the Spring Festival holiday from January 21 to February 4, 2025 (GMT+8). Pre-sales and after-sales service will reply to the information on February 5, 2025, and shipping will resume on February 8, 2025. Thank you for your support and trust in 2024. In 2025 and the future, we will bring better products and services to our friends.
Best wishes,