When the Antminer S19 Pro kernel log shows ERROR _ TEMP _ TOO _ HIGH, it may be the temperature sensor chip failure or the hash board chip failure; you can use the following methods to troubleshoot.
Troubleshooting:
a. Most temperature sensor chip problems are caused by chip pseudo soldering. It is necessary to measure the voltage and resistance of the corresponding chip, and the measured resistance can be compared with other hash boards of the same type or good hash boards.
b. If the temperature sensor chip is normal, it means that the chip, through which the temperature sensor circuit will pass through, may be abnormal.
Test method: use fluke 15b+ multimeter in DC gear and diode gear, connect the red test lead to the corresponding heat sink and test with the black test lead. Compare the measured chip data with the standard chip data. If an abnormality is found, it is recommended to replace the abnormal chip directly.
Click the article below to learn more!
>>How to judge the high - temperature protection of miners and solutions?
Dear Customers,
Hello everyone, as China is about to usher in the Spring Festival, international logistics will be suspended. Zeus Mining is scheduled to stop shipping on January 18, 2025, and start the Spring Festival holiday from January 21 to February 4, 2025 (GMT+8). Pre-sales and after-sales service will reply to the information on February 5, 2025, and shipping will resume on February 8, 2025. Thank you for your support and trust in 2024. In 2025 and the future, we will bring better products and services to our friends.