When the Antminer S9 backstage log shows do not read out ASIC 62 Hash Board & ASIC temperature, it may mean that the No.62 AISC chip of a single hash board of the S9 miner is damaged or the temperature sensor chip is faulty. You can troubleshoot by following the instructions below.
Troubleshooting:
First, check the model number of the temperature sensor chip next to chip 62. Then, ensure that the temperature sensor configuration file used by the TF card of the test fixture is consistent with the model of the temperature sensor chip of the tested hash board. If the models are inconsistent, change to a consistent temperature sensing profile, then power on the test fixture again and test. If the configuration files of the temperature sensor chips are consistent, replace the No.62 ASIC chip.
Click the article below to learn more!
>> How to replace Antminer S9 hash board temperature file?
Dear Customers,
Hello everyone, as China is about to usher in the Spring Festival, international logistics will be suspended. Zeus Mining is scheduled to stop shipping on January 18, 2025, and start the Spring Festival holiday from January 21 to February 4, 2025 (GMT+8). Pre-sales and after-sales service will reply to the information on February 5, 2025, and shipping will resume on February 8, 2025. Thank you for your support and trust in 2024. In 2025 and the future, we will bring better products and services to our friends.