Antminer S17e temperature sensor fault - S17e Kernel Log

The temperature sensor chip is mainly used to sense the temperature of the hash board and its surrounding environment. According to the Antminer S17e kernel log, the wrong temp sensor (98) type indicates that the temperature sensor chip is faulty. If such a situation occurs, you can troubleshoot according to the following steps.

wrong temp sensor type.jpg 

Troubleshooting:

Focus on checking the voltage and ground value of the No. 100 ASIC chip and the corresponding temperature sensor chip; if the voltage is abnormal, it is recommended to re-solder or replace the faulty BM1396 chip.

BM1396 chip.jpg 

Test method: Use the DC gear and diode gear of the fluke17B+ multimeter, connect the red test lead to the corresponding heat sink, and use the black test lead to test.

 

Click the article below to learn more!

>> Antminer Test Fixture for S17+, T17+, S17e, T17e, S19 series

>> S17e, T17e, S17+, T17+ Control Board Program Recovery

>> Antminer S17e Hash Board Repair Guide

0
About products purchase, please contact our sales manager:
[email protected]

About miner repair and after-sale issues, please contact the repair manager email:
[email protected]

For business cooperation, please contact:
[email protected]

COMPLAINTS & SUGGESTIONS
If you have any dissatisfaction during the transaction or have valuable suggestions for us, please contact us via this email address:
[email protected]
Attention!

Recently, many companies claiming to be mining companies imitate us and say that they are related to us, or that they are our branch companies, which has caused customers to be deceived. Please be careful not to believe any impostors, please check our correct contact information and beware of being deceived getting scammed, and losing money.
please check our right contact way: Here

CLOSE