The temperature sensor chip is mainly used to sense the temperature of the hash board and its surrounding environment. According to the Antminer S17e kernel log, the wrong temp sensor (98) type indicates that the temperature sensor chip is faulty. If such a situation occurs, you can troubleshoot according to the following steps.
Troubleshooting:
Focus on checking the voltage and ground value of the No. 100 ASIC chip and the corresponding temperature sensor chip; if the voltage is abnormal, it is recommended to re-solder or replace the faulty BM1396 chip.
Test method: Use the DC gear and diode gear of the fluke17B+ multimeter, connect the red test lead to the corresponding heat sink, and use the black test lead to test.
Click the article below to learn more!
>> Antminer Test Fixture for S17+, T17+, S17e, T17e, S19 series
Dear Customers,
Hello everyone, as China is about to usher in the Spring Festival, international logistics will be suspended. Zeus Mining is scheduled to stop shipping on January 18, 2025, and start the Spring Festival holiday from January 21 to February 4, 2025 (GMT+8). Pre-sales and after-sales service will reply to the information on February 5, 2025, and shipping will resume on February 8, 2025. Thank you for your support and trust in 2024. In 2025 and the future, we will bring better products and services to our friends.