A miner reported that after his Antminer S19j Pro ran for a while, the log showed pic_disable_dc_dc_common failed (as shown in the figure below). After checking the log, our technicians found that the PIC failed to open the DCDC circuit, which caused the miner to fail to complete the initialization.
Solution:
For this failure, you can troubleshoot according to the following steps:
1. Check whether the hash board cable is loose or damaged.
2. Use a programmer to rewrite the PIC program.
3. Check the output of the PIC chip (the normal voltage is around 3.3V), and replace the PIC chip if the voltage is abnormal.
Dear Customers,
Hello everyone, as China is about to usher in the Spring Festival, international logistics will be suspended. Zeus Mining is scheduled to stop shipping on January 18, 2025, and start the Spring Festival holiday from January 21 to February 4, 2025 (GMT+8). Pre-sales and after-sales service will reply to the information on February 5, 2025, and shipping will resume on February 8, 2025. Thank you for your support and trust in 2024. In 2025 and the future, we will bring better products and services to our friends.