When the miner reported that his log shows Chain 0 only find 47 asic, will power off hash board 0? How to troubleshoot and how solve this problem?
Fault description:
The no.1 hash board only finds 47 asic (a total of 126 asic), and the control board will power off the No.1 hash board. As a result, the initialization of the soc fails, and finally, the miner cannot operate normally.
Solution:
First, use the jig to test the No. 1 hash board, and then use the method of shorting "CO" according to the test result, first confirm whether the number reported by the jig test is correct, and then check the CLK, RET, CO, RI, BO signals of the chip voltage. Finally, according to the test results, find the chip with abnormal signal voltage and replace it.
Dear Customers,
Hello everyone, as China is about to usher in the Spring Festival, international logistics will be suspended. Zeus Mining is scheduled to stop shipping on January 18, 2025, and start the Spring Festival holiday from January 21 to February 4, 2025 (GMT+8). Pre-sales and after-sales service will reply to the information on February 5, 2025, and shipping will resume on February 8, 2025. Thank you for your support and trust in 2024. In 2025 and the future, we will bring better products and services to our friends.