The S9 Hydro uses water cooling to dissipate heat. Therefore, the miner will be defective due to abnormal temperature if the cooling is insufficient.
1. The water quality requirements of the miner
Deionized water, pure water, and purified water can be used.
To ensure the reliable long-term operation of the miner's water cooling system, it is recommended that the system's water quality meet the following requirements.
No. | Project | Control indicators | Illustrate |
1 | Total microbial count | <105CFU/mL | Microbial control of the reaction system |
2 | Turbidity | <10NTU | Suspended solids in the water quality of the reaction system |
3 | PH value | 6-9 | Indirect response to microorganisms |
4 | Conductivity | <1mS/cm | Ion concentration in the reaction water system |
2. Typical water quality problems
The water treatment machine does not filter the water in the system, and there are too many impurities in the water.